This aging cabinet is mainly used to test the charge and discharge cycles of lithium batteries. The test items mainly include: battery charging protection voltage, discharge protection voltage, capacity, etc. The equipment has four test steps: charging, discharging, shelving, and cycling. Test the battery according to the set process by editing the corresponding steps.
Advantages;
1. Single Point Control Technology
2. Each channel is independent of each other.
3. Anti-backup protection function
4. Automatic real-time data preservation
5. Two communication modes: serial port and network
Specifications
Input power |
AC220V±10%/50Hz |
|
|
Measuring Range |
0-100V |
|
Accuracy |
±(0.2% of reading +0.2% of range) |
|
Charging Range |
200-20000mA |
|
Charging Accuracy |
±(0.2% of reading +0.2% of range) |
|
Discharge Range |
200-40000mA |
|
Discharge Accuracy |
±(0.2% of reading +0.2% of range) |
Charge |
Constant Voltage Cut-off Current |
Minimum 200mA |
Capacity |
Accuracy |
±1% |
Power |
Discharge Power |
≤4KW |
Time |
Inspection Time |
Real-time Collection<2S |
|
Timing Range |
0-999h/step |
Data Recording Interval |
≥5S |
|
Middle Machine Version |
1:1 series |
|
Charge |
Charging Mode |
Constant Current and Constant Voltage Charging |
|
Cut-off condition |
Voltage, Current, Relative Time, Overcharge Protection |
Discharge |
Discharge mode |
Constant current discharge |
|
Cut-off condition |
Voltage, Relative Time and Over-discharge Protection |
Loop |
Cyclic measurement range |
1-999 times |
|
Single cycle step number |
100 |
Voltage and Current Detection Sampling |
Four-wire sampling |
|
Data Base |
Using SQL database to manage test data |
|
Upper computer communication mode |
Based on TCP/IP Protocol/Serial Port |
|
Data Output Mode |
EXCEL/TXT/Chart |
|
Communication Interface |
Mesh port |
|
Cabinet size |
800x520x1370mm(L*W*H) |
|
Spatial Dimension of Discharge Battery |
720x400x420mm(L*W*H) |