CE-6000 Module testing system is a high-precision charging and discharging equipment specially developed for high-power battery pack testing.
It has the characteristics of high dynamic response speed, high stability and accuracy, flexible configuration of multiple channels, etc. It supports pulse test, cycle life test, and working condition simulation test.
The system has multi-channel input and energy recovery functions, which can save a lot of electric energy consumed during the charging and discharging process.
Using bidirectional high-frequency DC conversion topology, combined with high-performance multi-channel 24-bit AD conversion chip, the sampling resolution is higher than that of traditional single-range devices.
Specifications:
Product Name |
Pack Line Testing Equipment AOT-6012n-20V50A-H |
AC Input Power |
AC380V±15% 50/60±5Hz |
Power factor |
≥99% |
THDi |
≤5% |
Input resistance |
≥1MΩ |
Input power |
14.1 KW |
Input Current |
21.5 A/phase |
Overall efficiency |
90% |
Noise |
≤65dB |
Voltage and current detection sampling |
Four-wire connection (same port for charging and discharging) |
Input power wiring
|
Three-phase five-wire |
Number of channels
|
12channels |
Channel characteristics |
CC-CV constant current source and constant voltage source adopt double closed-loop structure
|
Channel control mode |
independent control |
Channel parallel connection |
support channel parallel connection, pulse and analog tests are not supported after parallel connection |
Operating temperature
|
-10℃~40℃ (within the range of 25±10℃, the measurement accuracy is guaranteed: the accuracy drift is 0.005% of FS/℃)
|
Storage temperature
|
-20℃~50℃
|
Relative humidity of working environment |
≤70% RH (no water vapor condensation)
|
Storage environment relative humidity |
≤80% RH (no condensation) |
Device size W*D*H |
600*800*1300(mm) |
Measurement range per channel |
Charge: 0V~20V; Discharge: 2V~20V |
Minimum discharge voltage |
2V |
Resolution |
24bit |
Measurement range of each channel |
0.25A~50A |
Accuracy (independent range) |
±0.05% of FS |
Constant voltage cut-off current |
50mA |
Single channel output power |
1KW |
The output power of the whole machine |
12KW |
Current response time |
≤3ms |
Current conversion time |
≤6ms |
Minimum step time |
0.1s |